Enter/Exit Programming Mode Reading Parameters
58
WDI4600
Double Read Timeout
Double Read Timeout prevents a double read of the same label by setting the minimum time
allowed between reads of labels of the same symbology and data. If the unit reads a label and
sees the same label again within the specified timeout, the second read is ignored. Double Read
Timeout does not apply to scan modes that require a trigger pull for each label read.
$CSNDR0A(CR)
Double Read Timeout = 0.1 Second
$CSNDR14(CR)
Double Read Timeout = 0.2 Second
$CSNDR1E(CR)
Double Read Timeout = 0.3 Second
$CSNDR28(CR)
Double Read Timeout = 0.4 Second
$CSNDR32(CR)
Double Read Timeout = 0.5 Second
$CSNDR3C(CR)
Double Read Timeout = 0.6 Second
DEFAULT
$CSNDR46(CR)
Double Read Timeout = 0.7 Second